(Solved):
The power input to a 6-pole, 50Hz, 3-phase induction motor is 700W at no load and 10kW at ...
The power input to a 6-pole, 50Hz, 3-phase induction motor is 700W at no load and 10kW at full load. The no-load copper losses may be assumed negligible while the full-load stator and rotor copper losses are 295W and 310W respectively Find the full-load speed, shaft torque and efficiency of the motor, assuming rotational and core losses to be equal.